Guppy PRO Technical ManualV4.1.0
129
Controlling image capture
Software trigger
A software trigger is an external signal that is controlled via a status and control
register: 62Ch on page 201: to activate software trigger set bit [0] to 1.
The behavior is different dependent on the trigger mode used:
• Edge mode, programmable mode: trigger is automatically reset (self-
cleared).
• Level mode: trigger is active until software trigger register is reset
manually.
in advanced register 62Ch on page 201: set bit [0] to 0
in SmartView: Trig/IO tab, Stop trigger button
Debounce
Only for input ports:
There is an adjustable debounce time for trigger: separate for each input pin. The
debounce time is a waiting period where no new trigger is allowed. This helps
you to set exactly one trigger.
To set this feature in an advanced register: see chapter Debounce time on page
130.
To set this feature in SmartView: Trig/IO tab, Input pins table, Debounce col-
umn.
Note
• Switching trigger delay to ON also switches external Trig-
ger_Mode_0 to ON.
• This feature works with external Trigger_Mode_0 only.
Figure 69: Example of debounce time for trigger
Trigger
signal
Debounce time