Vue de la page 13
Prosilica GE Technical Manual V2.1.0
14
Specifications
Figure 1: Prosilica GE680 monochrome spectral response
Figure 2: Prosilica GE680C color spectral response (without IR cut filter)
0%
10%
20%
30%
40%
50%
60%
300 400 500 600 700 800 900 1000 1100
Quantum Efficiency
Wavelength [nm]
Measured with
clear cover glass
0%
5%
10%
15%
20%
25%
30%
35%
40%
45%
300 400 500 600 700 800 900 1000 1100
Quantum Efficiency
Wavelength [nm]
Measured with
clear cover glass
Red Green Blue